Skip to Main Content
<< Back | Return to Main COMAR Search Page

10 records match your request.

FileAbstract
26.11.39.00.htm 26.11.39.00. Title 26 DEPARTMENT OF THE ENVIRONMENT Subtitle 11 AIR QUALITY Chapter 39 Architectural and Industrial Maintenance (AIM) Coatings Authority: Environment Article, §1-404, 2-103, and 2-301―2-303, Annotated Code of Maryland
26.11.39.01.htm 26.11.39.01. 01 Applicability and Exemptions.. A. Except as provided in §B of this regulation, this chapter applies to a person who:. 1) Supplies, sells, offers for sale, or manufactures an architectural coating for use within the State; or2) Uses or applies an architectural coating within the State.. B. This chapter does not apply to the following products:. 1) Any architectural coating that is supplied, sold, offered for sale or manufactured for:. a) Use outside of the State; or.
26.11.39.02.htm 26.11.39.02. 02 Test Methods—Incorporation by Reference.. A. In this chapter, the following documents are incorporated by reference.. B. Documents Incorporated.. 1) Fire-Resistance Rating. The fire-resistance rating of a fire-resistive coating shall be determined by ASTM Test Method E119-08, “Standard Test Methods for Fire Tests of Building Construction and Materials”2) Gloss Determination. The gloss of a coating shall be determined by ASTM Test Method D523-89(1999) “Standard Test Method fo
26.11.39.03.htm 26.11.39.03. 03 Definitions.. A. In this chapter, the following terms have the meanings indicated.. B. Terms Defined.. 1) “Adhesive” means a chemical substance that is applied for the purpose of bonding two surfaces together other than by mechanical means.2) “Aerosol coating product” means a pressurized coating product containing pigments or resins that:. a) Dispenses product ingredients by means of a propellant; and. b) Is packaged in a disposable can for handheld application, or for use in
26.11.39.04.htm 26.11.39.04. 04 General Requirements and Standards.. A. VOC Content Limits.. 1) Except as provided in this regulation, a person may not manufacture, blend, repackage for sale, supply, sell, offer for sale, or apply within the State an architectural coating with a VOC content in excess of the corresponding limit specified in Regulation .05 of this chapter.2) Limits are expressed as VOC content, thinned to the manufacturer’s maximum thinning recommendation, excluding any colorant
26.11.39.05.htm 26.11.39.05. 05 VOC Content Limits.. Table 1. VOC Content Limits for Architectural and Industrial Maintenance Coatings.. Coating Category. VOC Content Limit (grams per liter). Flat coatings. 50. Non-flat coatings. 100. Non-flat-high gloss coatings. 150. Specialty coatings:. Aluminum roof coatings. 450. Basement specialty coatings. 400. Bituminous roof coatings. 270. Bituminous roof primers. 350. Bond breakers. Calcimine recoater. 475. Concrete curing compounds. Concrete/masonry sealers.
26.11.39.06.htm 26.11.39.06. 06 Container Labeling Requirements.. A. A person who manufactures an architectural coating subject to this chapter shall display the information listed in this regulation on the coating container or container label in which the coating is sold or distributed.B. Date Code.. 1) The date the coating was manufactured, or a date code representing the date of manufacture, shall be indicated on the label, lid, or bottom of the container.2) If the manufacturer uses a date code for a coat
26.11.39.07.htm 26.11.39.07. 07 Reporting Requirements.. A person who manufactures a coating subject to this chapter shall provide within 180 days of written request, data concerning the distribution and sales of architectural coatings, including:A. The name and mailing address of the manufacturer;. B. The name, address, and telephone number of a contact person;. C. The name of the coating product as it appears on the label;. D. The application coating category;.
26.11.39.08.htm 26.11.39.08. 08 Compliance Procedures.. A. Calculation of VOC Content.. 1) For the purpose of determining compliance with the VOC content limits in Table 1 of Regulation .05 of this chapter, the VOC content of a coating shall be determined using the following procedures, as applicable:a) With the exception of low solids coatings, determine the VOC content (regulatory) in grams of VOC per liter of coating thinned to the manufacturer’s maximum recommendation, excluding the volume of
26.11.39.9999.htm 26.11.39.9999. Administrative History Effective date: April 25, 2016 (43:8 Md. R. 497).
<< Back | Return to Main COMAR Search Page